è¹ö(chamber)Àü¹®ON-OFF¹× ¿¡ÀÌ¡ ¹ýÁ¤Àåºñ Á¦ÀÛ±³À°/ÁÖ¹®ÆǸÅÀåºñHAKKO(Çϲ¿ÀεαâÀü¹®)LED Á¶¸í Ư¼öÀåºñÀÚµ¿È­ s/wÁ¦Ç°Àü±ØºÀ/ºí·¹À̵å¹èÅ͸®ÃøÁ¤±â·¹ÄÚ´õDRUCK(¾Ð·Â)DRUCK(¿Âµµ)DRUCK(½Àµµ)Àεαâ/°ø±¸/ÅøEXSO Àεαâ/Åø/°ø±¸ÄÜÅ©¸®Æ®ÇظÓ/ÀÓÆÑÆ®ÇظÓ/½Ã¼³¹°Ç¥ÁؾÈÁ¤±â ¹× Ç¥ÁØ·¥ÇÁ BIT-937 , BIT-938 ¿¬¸·½ÃÇè¿ë¹èdz±â½Ã¼³¹°°ü¸®À¯Áö¹ýÁ¤ÀåºñµàÆù Ãæ°Ý½ÃÇè±â°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñƯ¼öÁ¦Ç°»ç°ü¸®´ÙÇ׸ñ/ȯ°æÃøÁ¤±â STARMRTER¾Ð·Â±â·Ï°èÇ¥¸éÀúÇ×ÃøÁ¤±â·¹º§±â¹Ì²ô·³ÀúÇ×ÃøÁ¤±â

DL708E2
°¡°Ý¹®ÀÇ

34901A
653,000¿ø

AI183
°¡°Ý¹®ÀÇ

34980A ä³ÎÈ®Àå ¿É¼Ç
°¡°Ý¹®ÀÇ

34970A ä³ÎÈ®Àå ¿É¼Ç
°¡°Ý¹®ÀÇ

34970A
2,030,000¿ø

U2781A
°¡°Ý¹®ÀÇ

U2356A
°¡°Ý¹®ÀÇ

U2355A
°¡°Ý¹®ÀÇ

U2354A
°¡°Ý¹®ÀÇ

   Home > Àεαâ/°ø±¸/Ư¼ö¼³ºñ/Á¦Á¶¹ýÁ¤Àåºñ > ·¹ÄÚ´õ > ·¹ÄÚ´õ/µ¥ÀÌÅͼöÁý±â
 
MODEL : 2625A   
Data Acquisition (ÀÔ·Â21CH/Ãâ·Â12CH)
   
 ÆǸŰ¡°Ý
: °¡°Ý¹®ÀÇ(VATº°µµ)
 Àû¸³±Ý : 0 ¿ø
 ³³±âÀÏ : 4ÁÖÀÏÀ̳»
 ¼ÒºñÀÚ°¡
: 460,000 ¿ø
 ±¸¸Å¼ö·®
: °³
 ´ë·®±¸¸Å½Ã °ßÀûÈÄ ±¸¸ÅÇÏ½Ã±æ ¹Ù¶ø´Ï´Ù!
 Ä«µå°¡´É¿©ºÎ : Ä«µå±¸¸ÅºÒ°¡
 
 
 

FlukeÀÇ Á¦Ç°°¡°ÝÀº ÀüÈ­¹®ÀǸ¸ °¡´ÉÇÕ´Ï´Ù.
 
   

¡á

ÇÏÀ̵å¶ó ½Ã¸®Áî 2625A´Â ¿Âµµ, Àü¾Ð, Àü·ù µî ¿©·¯°¡Áö ÃøÁ¤ÇÏ°íÀÚ ÇÏ´Â µ¥ÀÌŸ¿¡ ´ëÇÑ PC¿ÍÀÇ ¿¬°èµÈ ·¹ÄÚµå±â´ÉÀ» ¼öÇàÇÕ´Ï´Ù.

¡á

Àü¸éÆdzڿ¡¼­ ½±°Ô »ç¿ë¼³Á¤À» ¹Ù²Ü¼ö ÀÖÀ¸¸ç RS-232C¸¦ ÀÌ¿ëÇÏ¿© PC¿Í Åë½ÅÇÕ´Ï´Ù. ¶ÇÇÑ PC¸¦ ÀÌ¿ëÇÑ ´Ù¾çÇÑ ÄÁÆ®·Ñ ¹× ¼ÒÇÁÆ®¿þ¾î¸¦ ÀÌ¿ëÇÑ ºÐ¼® ¹× º¯È¯ÀÌ °¡´ÉÇÕ´Ï´Ù

¡á

ƯÈ÷³ª 0 - 60µµ ±îÁöÀÇ ±¤¹üÀ§ÇÑ ¿Âµµ¿µ¿ª¿¡¼­ »ç¿ëÀÌ °¡´ÉÇϸç ƯÈ÷ Áøµ¿À̳ª Ãæ°Ý¿¡ °­ÇÑ Æ¯Â¡À» °¡Áý´Ï´Ù.

¡á

Æ°Æ°ÇÑ ½ºÆ¿ÄÉÀ̽º¿Í ÀüÀÚÆÄ(ÀâÀ½)ÀÇ À¯ÀÔÀ» ¹æÁöÇÏ´Â ÀåºñÀÇ ½¯µå󸮴 2620A°¡ ³·Àº ¿µ¿ªÀÇ ÃøÁ¤¹üÀ§¿¡¼­µµ ³·Àº ¿ÀÂ÷À²À» À¯ÁöÇÏ´Â ºñ°áÀÔ´Ï´Ù.

¡á

À¯´Ï¹ö¼£ ÀԷ¸ðµâÀº ¾î¶² ¼¾¼­À¯ÇüÀ̳ª ¾î¶² ÀԷ½ÅÈ£µµ ä³Î¿¡ ¿¬°áµÇ¸ç ³»ºÎ ½ÅÈ£Á¶°ÇÀº ÀÚµ¿ÀûÀ¸·Î Á¤È®ÇÑ ±â´ÉÀ¸·Î ½ºÀ§Ä¡ ÇÕ´Ï´Ù

Spec ¹× Ư ¼º

»ó¼¼ »ç¾çÀº µ¥ÀÌŸ½ÃÆ® ÂüÁ¶ Çϼ¼¿ä

±â º» ±¸ ¼º

¡á

ä³Î

¾Æ³¯·Î±× ÀÔ·Â 21ä³Î
µðÁöÅÐ ÀÔ,Ãâ·Â°ú ¾Ë¶÷Ãâ·Â ÃÑ 12ä³Î
Totalizer 1

¡á

ÀԷ¹üÀ§

DCÀü¾Ð 90mV to 150/300V
ACÀü¾Ð 300mV to 150/300V
ÀúÇ× 300¿È to 10¸Þ°¡¿È
ÁÖÆļö 15Hz to 1MHz
RTD(PT100) -200µµ to 600µµ
TC(KŸÀÔ) -100 to 1372µµ (J,K,T,R,S,B,C,E,Nµî Áö¿ø)

¡á

±âº» DCÁ¤¹Ðµµ

0.018%

¡á

PCÀÎÅÍÆäÀ̽º RS232C, IEEE488

¡á

½Ã½ºÅÛº° È®Àå°¡´É ä³Î¼ö 21 to 42

¡á

ÃÖ°í ½ºÄµ¼Óµµ 17(Rdgs/s)

¡á

POWER 90-264V AC (50or60Hz) or 16V DC

¡á

¾ÈÀü IEC1010, ANSI/ISA-S82.01-1994, CSA-C22.2 ¹× CE½ºÅٴٵåÀÇ ÀÀ¿ë °¡´ÉÇÑ ¼½¼Ç¿¡ »óÀÀ
Technical Specifications
DC Volts Range: 90 mV to 300/150V
Resolution: 1 µV to 10 mV
Accuracy (3-Sigma)± 0.018%
AC Volts Range: 300 mV to 300/150V
Resolution: 10 µV to 10 mV
Accuracy: (3-Sigma)± 0.13%
Resistance Range: 300W to 10 MW
Resolution: 10 mW to 1 KW
Accuracy: (3-Sigma)± 0.013%
Frequency Range: 15 Hz to 1 MHz
Resolution: 0.01 Hz to 1 kHz
Accuracy: (3-Sigma)± 0.05%
RTD (Pt 100) Range: -200 to 600ºC
Resolution: 0.02ºC
Accuracy: (3-Sigma)± 0.05ºC
J Thermocouples Range: -100 to 760ºC
Resolution: 0.1ºC
Accuracy: (3-Sigma)± 0.39ºC
K Thermocouples Range: -100 to 1372ºC
Resolution: 0.1ºC
Accuracy: (3-Sigma)± 0.45ºC
T Thermocouples Range: -150 to 400ºC
Resolution: 0.1ºC
Accuracy: (3-Sigma)± 0.39ºC
Other Thermocouple types R, S, B, C, E, N
2625A Data Memory Specifications
2625A Data Storage Stores 2047 scans; stored with each scan: time stamp, all defined analog input channels, the status of four alarm outputs and eight digital I/O, and the totalizer count
Scan Contents Memory life: 5 years minimum; at 25ºC
  • Date and time stamp
  • All defined analog input channel values
  • Status of four alarm outputs and eight digital I/O
  • Totalizer count
/> />
2635A Memory Card Capacity Specifications
256k Card Size 4 Channels in Scan 8900
10 Channels in Scan 4800
20 Channels in Scan 2710
1M Card Size 4 Channels in Scan 36,860
10 Channels in Scan 19,860
20 Channels in Scan 11,210
2M Card Size 4 Channels in Scan 74,110
10 Channels in Scan 39,910
20 Channels in Scan 22,550
4M Card Size 4 Channels in Scan 149,039
10 Channels in Scan 80,251
20 Channels in Scan 45,359
General Specifications
Channel Capacity Analog Inputs: 21; Digital I/O & Alarm Outputs: 12 total; Totalizer: 1
Power 90V ac to 264V ac (50 Hz or 60 Hz), or 9V dc to 16V dc; less than 10W. (If both sources are applied simultaneously, the greater of ac or dc is used. At 120V ac the equivalent dc voltage is ~14.5V)
Temperature, Humidity (non-condensing) Operating: 0 to 28ºC, <=90% RH; 28ºC to 40ºC, <=75% RH; 40ºC to 60ºC, <=50% RH; Storage: -40ºC to 75ºC, 5 to 95% RH
Altitude Operating: 3050m (10,000 ft); Storage: 12,200m (40,000 ft)
Common Mode and Normal Mode Voltage 300V dc or ac rms (channels 0,1,11); 150V dc or ac rms (all other channels) IEC Overvoltage Category II.
Isolation Analog input to analog input, and analog input to any digital input: meets IEC 1010 for 300/150 volts reinforced and ANSI/ISA-S82.01-1988 and CSA 231 for 250 volts single insulation
Safety Complies with applicable sections of the IEC1010, ANSI/ISA-S82.01-1988, CSA231, UL 1244, CSA 556B, CE.
RF Emissions Passes FCC EMI Class A Equipment and VDE 0871B
Size 9.3 cm x 21.6 cm x 31.2 cm (3.67" x 8.50" x 12.28")
Weight 2.95 kg (6.5 lb)
Memory life 10 years typical for real-time clock, set-up configuration and measurement data in 2625A, memory cards typically 5 years for the 256 kB card
Interfaces RS-232C connector: nine pin male (DB-9P)
Signals TX, RX, DTR, GND
Modem Control Full duplex
Baud Rates (Set from front panel) 300, 600, 1200, 2400, 4800, 9600, 19.2k, 38.4k
Echo (Set from front panel) On/Off
Flow Control XON/XOFF
IEEE-488 (Optional, 2620A Only) Complies with IEEE-488.1 Standard; disables RS-232C Interface while in use

¹è¼ÛÁö¿ª : Àü±¹

¹è¼Ûºñ : 3,000ÀÔ´Ï´Ù.(µµ¼­,»ê°£,¿ÀÁö ÀϺÎÁö¿ªÀº ¹è¼Ûºñ°¡ Ãß°¡µÉ ¼ö ÀÖ½À´Ï´Ù.)
º» »óÇ°ÀÇ Æò±Õ ¹è¼ÛÀÏÀº 4ÁÖÀÏÀ̳»ÀÔ´Ï´Ù.(ÀÔ±Ý È®ÀÎ ÈÄ)
     ¼³Ä¡ »óÇ°ÀÇ °æ¿ì ´Ù¼Ò ´Ê¾îÁú¼ö ÀÖ½À´Ï´Ù.
     [¹è¼Û¿¹Á¤ÀÏÀº ÁÖ¹®½ÃÁ¡(ÁÖ¹®¼ø¼­)¿¡ µû¸¥ À¯µ¿¼ºÀÌ ¹ß»ýÇϹǷΠÆò±Õ ¹è¼ÛÀÏ°ú´Â Â÷ÀÌ°¡ ¹ß»ýÇÒ ¼ö ÀÖ½À´Ï´Ù.]

¹è¼Û±â°£ :ÁÖ¹®ÀÏ Æ÷ÇÔ 4ÁÖÀÏÀ̳»¿¡ »óÇ°À» ¹ÞÀ¸½Ç ¼ö ÀÖ½À´Ï´Ù. (¿¬ÈÞ/°øÈÞÀÏ Á¦¿ÜÀ̸ç, Çö±Ý ÁÖ¹®ÀÏ °æ¿ì ÀÔ±ÝÀÏ ±âÁØÀÔ´Ï´Ù.)