Ȩ | ·Î±×ÀÎ | ȸ¿ø°¡ÀÔ | Àå¹Ù±¸´Ï | ¹è¼ÛÁ¶È¸
     
    
Àü±âÀüÀÚ°èÃø±â/¹ýÁ¤Àåºñ
½ºÄÚÇÁLCR/ÀÓÇÇ´ø½º¸ÖƼ¸ÞÅÍŬ·¥ÇÁ¸ÞŸÁÖÆļöÄ«¿îÅÍÆã¼Ç¹ß»ý±âÀý¿¬/Á¢ÁöÀúÇ×±âÇϳ׽ºÅ×½ºÅͺÎÇ°Å×½ºÅÍÁ¦Á¶Ç°¸ñ/¹ýÁ¤ÀåºñĶ¸®ºê·¹ÀÌÅÍ´©¼³Àü·ù°è·ÎÁ÷ºÐ¼®±âÇ÷°½º¸ÞŸ¼­ÁöÅ×½ºÅÍÆ®·£½ºÅ×½ºÅÍÆÄ¿ö¸ÞŸ°Ë»ó±â¹ýÁ¤/Çü½Ä½ÂÀÎÁ¦Ç°(1)¹ýÁ¤/Çü½Ä½ÂÀÎÁ¦Ç°(2)ATTEN // KORAD¿¡³ÊÁöÁø´ÜÀåºñÈ©ÅØÄÚ¸®¾Æ/hopetech koreaOWONFLUKEÃÑÆÇÀúÇ×°¡°¨±âÂ÷´Ü±âÅ×½ºÅÍHIOKIƯÆÇÇѱ¹»êDMM6ŸÁ¡±â·Ï°èLUTRON(·çÆ®·Ð)YOKOKAWA Àåºñ(ÃÑÆÇÃë±ÞÀåºñ)Àü¾Ð/Àü·ù probeGWINSTEK(±»ÀªÆ¯ÆÇÀåºñ)CCTVÅ×½ºÅͱâÁ¢Áö¿¬¼Ó¼º½ÃÇè±âscopeÇÁ·ÎºêÀÚµ¿Àü¾ÐÁ¶Á¤±âÀÓÇÇ´ø½º¸ÞÅÍ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñAPPLENTµðÁöÅÐ ´Ù±â´É°èÃø±â¹Ì²ô·³¹æÁö,µµ¸·Çü¹Ù´ÚÀç¹ýÁ¤/Çü½Ä½ÂÀÎÁ¦Ç°/Á÷Á¢»ý»ê(3)

Fluke-725EX
3,400,000¿ø

FLUKE-744 INTL ÇÁ·Î¼¼½º Ķ¸®ºê·¹ÀÌÅÍ (°èÀå¿ë)
°¡°Ý¹®ÀÇ

FLUKE-705
°¡°Ý¹®ÀÇ

FLUKE-707
958,000¿ø

FLUKE-707EX
°¡°Ý¹®ÀÇ

FLUKE-741B INTL
°¡°Ý¹®ÀÇ

FLUKE-743B INTL
°¡°Ý¹®ÀÇ

FLUKE-744 INTL
°¡°Ý¹®ÀÇ

FLUKE-787
°¡°Ý¹®ÀÇ

FLUKE-789
°¡°Ý¹®ÀÇ

   Home > Àü±âÀüÀÚ°èÃø±â/¹ýÁ¤Àåºñ > FLUKEÃÑÆÇ > Ķ¸®ºê·¹ÀÌÅÍ
 
MODEL : FLUKE-789   
ProcessMeter (DMM+LOOP±³Á¤±â/1§Ë/AC/DC/ÀúÇ×/µµÅë/ ÁÖÆļö/ DC LoopÃâ·Â/½Ã¹Ä·¹À̼Ç/·¹ÄÚ´õ±â´É)
   
 ÆǸŰ¡°Ý
: °¡°Ý¹®ÀÇ(VATº°µµ)
 Àû¸³±Ý : 0 ¿ø
 ³³±âÀÏ : 4ÁÖÀÏÀ̳»
 ¼ÒºñÀÚ°¡
: 460,000 ¿ø
 ±¸¸Å¼ö·®
: °³
 ´ë·®±¸¸Å½Ã °ßÀûÈÄ ±¸¸ÅÇÏ½Ã±æ ¹Ù¶ø´Ï´Ù!
 Ä«µå°¡´É¿©ºÎ : Ä«µå±¸¸ÅºÒ°¡
 
 
 

FlukeÀÇ Á¦Ç°°¡°ÝÀº ÀüÈ­¹®ÀǸ¸ °¡´ÉÇÕ´Ï´Ù.
 
   

¡á

Fluke 789 ProcessMeter.(Double your power = DMM + Loop Calirators)

¡á

Fluke-789Àº DMM°ú LOOP±³Á¤±â(Calibrator)°¡ °áÇյǾú°í »ê¾÷ºÐ¾ß¿¡¼­ °¡Àå »ç¿ëµµ°¡ ³ôÀº Á¤¹Ð±Þ DMMÀ» ±âº»À¸·Î Çϸç, HART ¸ðµå¿¡¼­ÀÇ 24V Àü¿ø°ø±ÞÀ» ÇÒ ¼ö ÀÖ½À´Ï´Ù

Spec ¹× Ư ¼º

»ó¼¼ »ç¾çÀº ÷ºÎ È­ÀÏ ÂüÁ¶ Çϼ¼¿ä

¡á

24V ·çÇÁ Àü¿ø°ø±Þ

¡á

100% ´õ Ä¿Áø µà¾ó µð½ºÇ÷¹ÀÌ

¡á

È®ÀåµÈ ¹é¶óÀÌÆ® ±â´É

¡á

0 ~ 100% mA SpanCheck(4 ~ 20mA)

¡á

¿ëÀÌÇÑ Ç»Áî, º£Å͸® ±³È¯

¡á

Á¤¹ÐÇÑ 1000V, 440mA True-rms µðÁöÅÐ ¸ÖƼ¹ÌÅÍ

¡á

20KHz ÁÖÆļö ÃøÁ¤

¡á

ÃÖ¼Ò/ÃÖ´ë/Æò±Õ/Ȧµå(hold) ¸ðµå

¡á

´ÙÀÌ¿Àµå Å×½ºÆ® & ¿¬¼ÓÀûÀÎ ºñÇÁÀ½

¡á

20mA dc Àü·ù ¼Ò½º/ ·çÇÁ Ķ¸®ÇÁ·¹ÀÌÅÍ/ ½Ã¹Ä¿¡ÀÌÅÍ

¡á

¸Þ´º¾ó ½ºÅÛ, ¿ÀÅä ½ºÅÛ ±â´É

Measurement Accuracy

V dc : Range and Resolution
400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
Best Accuracy (% of reading + LSD)
0.1 % + 1

V ac (true-rms) : Range and Resolution
400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
Best Accuracy (% of reading + LSD)
0.7 % + 2

mA dc : Range and Resolution
30.000 mA
Best Accuracy (% of reading + LSD)
.05 % + 2

A dc : Range and Resolution
1.000 A (0.440 A continuous)
Best Accuracy (% of reading + LSD)
0.2 % + 2

A ac : Range and Resolution
1.000 A (0.440 A continuous)
Best Accuracy (% of reading + LSD)
1 % + 2

Resistance : Range and Resolution
400.0 Ohms, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M
Best Accuracy (% of reading + LSD)
0.2 % + 1

Frequency (0.5 Hz to 20 kHz) : Range and Resolution
199.99 Hz, 1999.9 Hz, 19.999 kHz
Best Accuracy (% of reading + LSD)
.005 % + 1

Diode Test : Range and Resolution
2.000 V (shows diode voltage drop)
Best Accuracy (% of reading + LSD)
2 % + 1

Continuity : Range and Resolution
Beeps for resistance < approx. 100 ohms

Output Function

DC Current Output(Internal battery operation)
Range and Resolution
0.000 to 20.000 mA or 4.000 to 20.000 mA
(selectable at power-up)
Over-range to 24.000 mA
Drive Capability (% of span)
24 V compliance, or,1,200 Ohms, @ 20 mA
Accuracy
.05 %

DC Current Simulate (Ext. 24 Volt loop supply)
Range and Resolution
0.000 to 20.000 mA or 4.000 to 20.000 mA,
(selectable at power-up)
Over-range to 24.000 mA
Drive Capability (% of span)
1000 Ohms, @ 20 mA
Accuracy
.05 %

24 V Loop Supply : Range and Resolution
Minimum 24 V
Drive Capability (% of span)
250 Ohms @ 20 mA
Accuracy
Ø 24 V
Ø

Current Adjustment Modes : Range and Resolution
Manual: 0.001 mA, 0.1 mA, 25 % and 100 % step
Automatic: Slow Ramp, Fast Ramp, 25 % step
*Temperature range of 18 °C to 28 °C, for one
year after caibration

General Specifications

Maximum voltage applied between any jack and earth ground: 1000 V RMS

Storage temperature: -40 °C to 60 °C

Operating temperature: -20 °C to 55 °C

Temperature coefficient: 0.05 x(specified accuracy)perC (for temperatures < 18°C or > 28°C)

Relative humidity : 95 % up to 30 °C; 75 % up to 40 °C

45 % up to 50 °C; 35 % up to 55 °C

Vibration: Random, 2 g, 5-500 Hz

Shock: 1 meter drop test

Safety: Designed in accordance with EN61010, ANSI/ISA S82.01-1994 and CAN/CSA C22.2
No. 1010..1-92 Over-voltage Category III

Size: 50 mm H x 100 mm W x 203 mm L (1.97 in H x 3.94 in W x 8.00 in L)

Weight: 600 g (1.3 lbs)

Battery: Four AA alkaline batteries

Battery life: 140 hours typical (measurement),

10 hours typical (sourcing 12 mA)

Warranty: 3 years


  


  


  


¹è¼ÛÁö¿ª : Àü±¹

¹è¼Ûºñ : 3,000ÀÔ´Ï´Ù.(µµ¼­,»ê°£,¿ÀÁö ÀϺÎÁö¿ªÀº ¹è¼Ûºñ°¡ Ãß°¡µÉ ¼ö ÀÖ½À´Ï´Ù.)