Home >
Àü±âÀüÀÚ°èÃø±â/¹ýÁ¤Àåºñ >
Á¦Á¶Ç°¸ñ/¹ýÁ¤Àåºñ >
GOODWILL |
|
|
|
|
|
|
|
|
|
AC/DC/IR/GB Electrical Safety Tester , 200VA
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Spec ¹× Ư ¼º
|
Spec ¹× Ư
¼º |
¡á |
200VA AC Test Capacity
|
¡á |
AC/DC Withstanding Voltage Test & Insulation Resistance Test &
Ground Bond Test
|
¡á |
Arc Detection
|
¡á |
Zero Crossing Turn-On Operation Switch
|
¡á |
Controllable Ramp-Up Time
|
¡á |
True RMS Cut-Off Current Measurement
|
¡á |
Automatic FAIL Indicator of Alarm Lamp and Buzzer
|
¡á |
9 pins Remote Control for START, RESET, and Test Result Output
|
¡á |
Scanner Box for Automatic Test (Option)
|
¡á |
nterface : RS-232C(Standard), GPIB(Option)
|
AC HI-POT SPECIFICATIONS |
Voltage Range |
0.100 ~ 5.000kV |
Voltage Resolution |
5V |
Voltage Regulation |
1% + 5 V |
Voltage Accuracy |
±1% of reading ±10 V (above 500V) |
Max. Current |
40mA, (above 500V) |
Current Limit |
0.10 ~ 40mA, 0.02mA (resolution) |
Current Accuracy |
±1% of reading ±80¥ìA |
DC HI-POT SPECIFICATIONS |
Voltage Range |
0.100 ~ 6.000kV |
Voltage Resolutoin |
5V |
Voltage Regulation |
1% + 5 V |
Voltage Accuracy |
±1% of reading ±10 V (above 500V) |
Max. Current |
10mA, (above 500V) |
Current Limit |
0.10~10mA, 0.01mA (resolution) |
Current Accuracy |
±1% of reading ±50¥ìA |
INSULATION RESISTANCE SPECIFICATIONS |
DC Voltage |
50V/100V/500V/1000V |
Resistance Range |
1 ~ 9900M(500V,1000V); 1 ~ 2000M(50V,100V) |
Resistance Accuracy |
50V/100V 1~50M¥Ø: ±5% of reading
±1Count 51~200M¥Ø: ±10% of reading ±1Count 201M~1990M¥Ø: ±20% of reading
±1Count |
|
500V/1000V 1~500M¥Ø: ±5% of reading
±1Count 501~2000M¥Ø: ±10% of reading ±1Count 2001M~9900M¥Ø: ±20% of reading
±1Count |
GROUND BOND SPECIFICATIONS |
Voltage Range |
Max. 8V (DC) |
Current Range |
3 ~ 42A |
Current Resolution |
0.02A |
Current Accuracy |
1% of reading 0.2A(3A~8A) |
Ground Bond |
1% of reading 50mA(9A~42A) |
Resistance Test |
0 ~ 620m¥Ø |
Resistance Resolution |
0 ~ 600m¥Ø(100¥ì¥Ø) |
Resistance Accuracy |
±1% of reading 3 m¥Ø |
Test Method |
Four terminals test mode |
ARC DETECT |
Detect Current |
40 level (1 ~ 40mA) |
INTERFACE |
Remote I/O |
Standard |
RS-232C |
Standard |
Scan |
Standard |
Real Panel Output |
Standard |
GPIB |
Option |
Scanner Box |
Option (HSB-001-1 : 8ch HV+8ch GB ; HSB-001-2 : 16ch
HV) |
POWER SOURCE |
AC 100V, 120V, 220V, 230V ± 10%,
50/60Hz |
|
|
ACCESSORIES |
|
Instruction manual x 1 Power cord x 1 Test leads GHT-105A
x 1, GTL-115 x 1 |
DIMENSIONS & WEIGHT |
330(W) x 149(H) x 446(D)
mm Approx.15kg |
|
|
|
¹è¼ÛÁö¿ª : Àü±¹
¹è¼Ûºñ : 3,000ÀÔ´Ï´Ù.(µµ¼,»ê°£,¿ÀÁö ÀϺÎÁö¿ªÀº ¹è¼Ûºñ°¡ Ãß°¡µÉ ¼ö ÀÖ½À´Ï´Ù.)
º» »óÇ°ÀÇ Æò±Õ ¹è¼ÛÀÏÀº 4ÁÖÀÏÀ̳»ÀÔ´Ï´Ù.(ÀÔ±Ý È®ÀÎ ÈÄ)
¼³Ä¡ »óÇ°ÀÇ °æ¿ì ´Ù¼Ò ´Ê¾îÁú¼ö ÀÖ½À´Ï´Ù.
[¹è¼Û¿¹Á¤ÀÏÀº ÁÖ¹®½ÃÁ¡(ÁÖ¹®¼ø¼)¿¡ µû¸¥ À¯µ¿¼ºÀÌ ¹ß»ýÇϹǷΠÆò±Õ ¹è¼ÛÀÏ°ú´Â Â÷ÀÌ°¡ ¹ß»ýÇÒ ¼ö ÀÖ½À´Ï´Ù.]
¹è¼Û±â°£ :ÁÖ¹®ÀÏ Æ÷ÇÔ 4ÁÖÀÏÀ̳»¿¡ »óÇ°À» ¹ÞÀ¸½Ç ¼ö ÀÖ½À´Ï´Ù. (¿¬ÈÞ/°øÈÞÀÏ Á¦¿ÜÀ̸ç, Çö±Ý ÁÖ¹®ÀÏ °æ¿ì ÀÔ±ÝÀÏ ±âÁØÀÔ´Ï´Ù.)
|
|
|
|
|